2"x4"x16" NaI(Tl) Scintillation Detector
The Model NAI2/4/16P3.5 Scintillation Detector is a hermetically sealed assembly which includes a high resolution 2″x4″x16″ NaI(Tl) scintillator, a 3″...
2"x4"x16" NaI(Tl) Scintillation Detector
The Model NAI2/4/16P3.5 Scintillation Detector is a hermetically sealed assembly which includes a high resolution 2″x4″x16″ NaI(Tl) scintillator, a 3″ photomultiplier tube, an internal magnetic/light shield, an Aluminum housing and a 14-pin connector. This kind of 14-pin NaI(Tl) detectors have good energy resolution(≤8.5%@662keV) and stability, their standard 14-pin connector can be easily inserted in plug-on photomu...
- ManufacturerOST Photonics
- CategoryScintillator
- Lead TimeQuoted per order
- CustomizationSize, orientation and surface finish to drawing
The Model NAI2/4/16P3.5 Scintillation Detector is a hermetically sealed assembly which includes a high resolution 2″x4″x16″ NaI(Tl) scintillator, a 3″ photomultiplier tube, an internal magnetic/light shield, an Aluminum housing and a 14-pin connector.
This kind of 14-pin NaI(Tl) detectors have good energy resolution(≤8.5%@662keV) and stability, their standard 14-pin connector can be easily inserted in plug-on photomultiplier tube(PMT) base or digital Multi-Channel Analyzer(MCA) for Gamma-ray detection systems.
The Model NAI2/4/16P3.5 Scintillation Detector is a hermetically sealed assembly which includes a high resolution 2″x4″x16″ NaI(Tl) scintillator, a 3″ photomultiplier tube, an internal magnetic/light shield, an Aluminum housing and a 14-pin connector.
This kind of 14-pin NaI(Tl) detectors have good energy resolution(≤8.5%@662keV) and stability, their standard 14-pin connector can be easily inserted in plug-on photomultiplier tube(PMT) base or digital Multi-Channel Analyzer(MCA) for Gamma-ray detection systems.
Overview
Photomultiplier Tube Specifications
| Spectral Response Range | 300-650 mm | |
| Peak Wave-length (nm) | 420 mm | |
| Photocathode Minimum Effective Area | 70 mm | |
| Photocathode Material | Bialkali | |
| Window Material | Borosilicate glass | |
| Dynode Structure/Stages | Box-and-grid/8 | |
| Cathode Luminous Sensitivity | Min. | 80 μA/lm |
| Typ. | 110 μA/lm | |
| Cathode Blue Sensitivity | Min. | 10 μA/lm |
| Typ. | 12 μA/lm | |
| Anode Luminous Sensitivity | Min. | 3 A/lm @1000V |
| Typ. | 30 A/lm @1000V | |
| Anode Dark Current | Typ. | 2 nA @1000V |
| Max. | 10 nA @1000V | |
| Anode Gain Typ. | 2.73×105 | |
| Anode to Cathode Voltage (DC) | Max. | 1500 V |
| Rise Time | Typ. | 8 ns |
| Operating Ambient Temperature | -30~+50℃ | |
| Suitable Socket | E678-14W |

Connection Way

Other Scintillation Detector Assemblies Materials
Request A Quote For 2"x4"x16" NaI(Tl) Scintillation Detector
Send us your dimensions, orientation, surface finish and quantity. Our engineers reply with a technical proposal and price.
Buyer Questions
What is the spectral response range of the 2"x4"x16" NaI(Tl) Scintillation Detector?
What is the peak wave-length of the 2"x4"x16" NaI(Tl) Scintillation Detector?
What is the photocathode minimum effective area of the 2"x4"x16" NaI(Tl) Scintillation Detector?
What is the photocathode material of the 2"x4"x16" NaI(Tl) Scintillation Detector?
How do I get a quotation for the 2"x4"x16" NaI(Tl) Scintillation Detector?
Can the 2"x4"x16" NaI(Tl) Scintillation Detector be made to a custom specification?
Who manufactures the 2"x4"x16" NaI(Tl) Scintillation Detector?
Tell Us What You Need
Send your specification, quantity and destination port. Our engineers reply with a technical proposal and a confirmed lead time.