[email protected]+86-799-7618678

DIN 42531 10NF250A Transformer Bushing

DIN 42531 10NF250A transformer bushing tested to IEC 60137. Range covers 1 kV to 52 kV and up to 5000 A with creepage distances for all environmental conditions.

High Voltage Transformer Bushings production

  • Home
  • Products
  • High Voltage Transformer Bushings
  • DIN 42531 10NF250A Transformer Bushing

Product Overview

A DIN 42531 bushing in the 10NF250A pattern, connecting transformers and generators to high voltage transmission lines. It sits in a range that covers 1 kV to 52 kV and up to 5000 A with a choice of creepage distances for different environmental conditions. All outdoor bushings are manufactured and tested to IEC 60137, with the detail governed by either the historical DIN specification or the current EN 50386 and EN 50180 range.

  • DIN 42531
  • EN 50180
  • EN 50386
  • IEC 60137

Why Buyers Choose This Part

  • Tested to IEC 60137 so test evidence is available for the specification file
  • Historical DIN and current EN patterns both kept in production
  • Creepage distances selectable to suit the environmental conditions
  • Screwed conductor air end termination as the standard arrangement

Where It Is Used

  • 10 kV class transformer terminal boards drawn to DIN 42531
  • Generator connections into high voltage transmission networks
  • Specifications that reference a discontinued DIN standard
  • Distribution transformer manufacture needing a range of ratings

Who It Suits

  • Distribution and power transformer manufacturers
  • Generator package builders
  • Utilities and distributors buying against DIN references

What Goes Wrong Without The Right Part

  • Drawings referencing DIN standards no longer maintained
  • Missing IEC 60137 test evidence at specification review
  • Creepage class chosen without reference to the site environment
  • Suppliers who carry only the EN range and not the DIN patterns

How It Is Built

  • DIN 42531 10NF250A pattern
  • Range covers 1 kV to 52 kV and up to 5000 A
  • Manufactured and tested by IEC 60137
  • Detail governed by historical DIN or current EN 50386 and EN 50180
  • Screwed conductor air end termination
  • Various creepage distances for all environmental conditions

Published Figures For This Product

Every value below comes from the manufacturer data for this item. Figures not listed are confirmed against the drawing before an order is placed.

DIN 42531 10NF Pattern250 A

Materials

  • Electrical porcelain shell
  • Electrolytic copper or aluminium alloy conductor

Process

  • Shell forming
  • Glazing
  • Firing
  • Conductor assembly
  • Testing to IEC 60137

Testing

  • Routine testing in accordance with IEC 60137
  • Creepage verification against the specified class
  • Termination thread and contact inspection

Certification

  • Manufactured and tested by IEC 60137
  • Built to DIN 42531, EN 50180 and EN 50386
  • ISO 9001 quality management system

Customisation Options

  • Ratings from 1 kV to 52 kV and up to 5000 A
  • Creepage distance chosen for the site environment
  • Air end termination to your connection type

How It Compares

DIN 42531 20NF-250ASame standard and the same 250 A current rating at a higher voltage class. The NF number sets the voltage, so match it to the transformer.
EN 50180 bushingsEN is the current specification set, DIN the historical one. Both remain in production because transformer drawings still reference both.

Before You Order And After It Arrives

  • Confirm whether your drawing quotes DIN 42531 or the EN equivalent
  • State the site environmental conditions so the creepage class is right
  • Ask for IEC 60137 test documentation if the specification requires it
  • Check the air end termination type matches your connection

DIN 42531 10NF250A Transformer Bushing Questions

Related Products

High Voltage Transformer Bushings

DIN 10NF250A Transformer Bushing For Oil-Immersed Transformers

High Voltage Transformer Bushings

  • DIN 10NF Pattern 250 A

AS 15/50 Transformer Bushing Insulator 15kV

High Voltage Transformer Bushings

  • Voltage 15 kV
  • Height 485 mm
  • Diameter 101 mm

AS 24/315 Transformer Bushing Insulator 24kV

High Voltage Transformer Bushings

  • Voltage 24 kV
  • Height 505 mm
  • Diameter 108 mm

GB BLQ-10/315 Transformer Bushing Insulator 10kV

  • Voltage 10 kV
  • Height 240 mm
  • Diameter 115 mm

Related Cases Guides And Applications

DIN EN And ANSI Transformer Bushing Standards Explained

Distribution Transformer Manufacturers

Power Utilities And Substations

Manufacturing To Your Drawing Or Sample

Selecting Creepage For The Pollution At Your Site

Quote For DIN 42531 10NF250A Transformer Bushing

Send the quantity and any drawing you have. Enquiries are answered within 24 hours, and we produce to customer drawings and samples.

Product Photographs

DIN 42531 10NF250A transformer bushing ceramic insulator10NF250A bushing screwed conductor terminationDIN 42531 10NF250A bushings grouped for inspection10NF250A bushing brass rod conductor detailAS 15/50 transformer bushing insulator for 15kVAS 24/315 transformer bushing insulator for 24kVGB BLQ-10/315 transformer bushing insulator for 10kV

Related Products

18kV 25A high voltage ANSI transformer bushing

18kV 25A HV ANSI Transformer Bushing

18 kV 25 A ANSI transformer bushing in the ANSI-18/50 body. 541 mm height, 480 mm creep distance, 8 single umbrella sheds, 3.5 kg, meets ANSI performance standards.

View Details →
24kV to 36kV high voltage porcelain transformer bushing

24kV To 36kV HV Porcelain Transformer Bushing

High voltage porcelain transformer bushing covering 24 kV to 36 kV. Insulates leading wires and provides mechanical support inside the transformer. Made to drawing.

View Details →

Request a Quote

We reply to every enquiry within one business day. Write to us directly by email or WhatsApp — both reach our sales desk immediately.